50-question quiz 0 of 50 questions answered 1. Circuits and basic electricity · Questions 1–10
1. What is a series circuit? A. Components connected between the same two nodes B. A circuit that always uses alternating current C. Components connected in a single current path D. A circuit with no resistance 2. What is a parallel circuit? A. Branches connected between the same two nodes B. A chain with only one current path C. A circuit that only runs on batteries D. A circuit with no voltage 3. In a series circuit, which quantity is the same through every component? A. The resistance of each component B. The voltage drop across each component C. The power of each component D. Current 4. Two resistors are connected in parallel across an ideal 24 V source. What is the voltage across each branch? A. 12 V B. 24 V C. 48 V D. It depends only on the value of each resistor 5. Which unit is used to express voltage? A. Amperes (A) B. Volts (V) C. Ohms (Ω) D. Hertz (Hz) 6. Which unit is used to express electric current? A. Volts (V) B. Watts (W) C. Ohms (Ω) D. Amperes (A) 7. Which unit is used to express electrical resistance? A. Ohms (Ω) B. Hertz (Hz) C. Amperes (A) D. Volts (V) 8. Ideal exercise: 24 V is applied across an 8 Ω resistor. What current flows? A. 8 A B. 16 A C. 3 A D. 192 A 9. What characterizes direct current (DC)? A. The direction reverses periodically B. It always has a frequency of 60 Hz C. It can only exist in a parallel circuit D. Charge flows in only one direction 10. What characterizes alternating current (AC)? A. It always flows in only one direction B. The direction of current changes periodically C. It always has a voltage of 240 V D. It cannot power a motor 2. Multimeters and measurements · Questions 11–20
11. On a typical multimeter, where does the black test lead connect? A. To COM B. Exclusively to the A input C. To any red input D. To the rotary selector 12. To measure voltage, which input is used for the red test lead? A. The A current input B. The mA current input C. The input marked V D. Every input works the same way 13. In a measurement diagram, how is a voltmeter connected relative to the component? A. In series, by opening the current path B. In parallel, across its two measurement points C. With both leads connected to the same terminal D. In place of the circuit protection 14. To measure current using a multimeter's current inputs, how is the instrument shown in the diagram? A. In series with the branch being measured B. In parallel with the source C. In parallel with any resistor D. Disconnected from the circuit 15. To measure a load's current with a clamp meter, what goes inside the jaws? A. The outgoing and return conductors together B. The equipment housing C. The refrigerant pipe D. A single conductor feeding the load 16. Before measuring resistance or continuity, how must the circuit be prepared? A. With the compressor running B. With the electrical protection bypassed C. De-energized, with absence of voltage verified and stored energy safely discharged D. By only turning off the thermostat display 17. Does a continuity beep prove an exact resistance of 0 Ω? A. Yes, it always means exactly 0 Ω B. Yes, but only with alternating current C. No; it indicates resistance below the instrument's threshold D. No; it always indicates an open circuit 18. A periodic 60 Hz signal completes: A. 60 volts per second B. 60 amperes per minute C. One cycle every 60 seconds D. 60 cycles per second 19. Which multimeter function does the Ω symbol identify? A. AC voltage B. Resistance C. Frequency D. Direct current 20. Does displaying more decimal places guarantee greater accuracy? A. No; resolution and accuracy are different characteristics B. Yes, each decimal place eliminates all error C. Yes, even if the probe is damaged D. Yes, regardless of the measurement range 3. Refrigerants and pressure charts · Questions 21–30
21. Before choosing a P–T chart, what equipment information do you need? A. Only the thermostat brand B. Only the size of the home C. The color of the outdoor unit D. The exact refrigerant designation on the nameplate and in the manual 22. What does a refrigerant P–T chart relate? A. Pressure and saturation temperature B. Fan voltage and amperage C. Thermostat temperature and monthly consumption D. Return-air pressure and airflow 23. Can a single pressure reading confirm the correct refrigerant charge under every condition? A. Yes, if it matches any chart found online B. Yes, if the pressure gauge is digital C. No; the manufacturer's required conditions and measurements are needed D. Yes, if the equipment cools for a few minutes 24. According to Arkema 2025, at a saturation temperature of 40 °F, what tabulated pressure corresponds to R-410A? A. 68.6 psig B. 118.8 psig C. 318.6 psig D. 35.0 psig 25. According to the same chart, what pressure corresponds to R-32 at 40 °F? A. 121.0 psig B. 325.7 psig C. 80.2 psig D. 63.2 psig 26. For R-454B at 40 °F, what pressure appears in the vapor/dew column of Arkema 2025? A. 112.0 psig B. 107.0 psig C. 290.9 psig D. 300.8 psig 27. Honeywell lists these temperatures at 110 psig: average 40.0 °F, bubble 38.9 °F and dew 41.1 °F. Which value would you use to calculate subcooling? A. 40.0 °F B. 41.1 °F C. 110 °F D. 38.9 °F 28. According to Arkema, which pair is classified A2L? A. R-410A and R-32 B. R-410A and R-454B C. R-32 and R-454B D. All three are A1 29. In the R-454B chart, bubble and dew temperatures differ at the same pressure. What should you do? A. Always use the average for every calculation B. Use the column appropriate for the measurement C. Use either column interchangeably D. Replace the chart with an R-410A chart 30. Is it correct to mix different refrigerants while charging a system? A. Yes, if their pressures are similar B. Yes, if both containers are the same color C. Yes, as long as only a small amount is added D. No; cross-contamination between refrigerants must be avoided 4. System vacuum and microns · Questions 31–40
31. What is the purpose of evacuating a refrigerant circuit that has been prepared for evacuation? A. To increase the amount of refrigerant B. To automatically repair any leak C. To remove moisture and noncondensable gases D. To clean the air filter 32. In a vacuum test, a reading in microns of mercury represents: A. Absolute pressure B. Sound level C. Pump flow rate D. Refrigerant temperature 33. Comparing absolute pressure only, which reading represents a deeper vacuum? A. 500 microns B. 1,000 microns C. 300 microns D. 1,500 microns 34. Which instrument does Lennox specify for checking a deep vacuum? A. Only a conventional pressure gauge in psig B. An electronic vacuum gauge calibrated in microns C. A clamp meter D. An ambient thermometer 35. According to Fieldpiece, where should the vacuum gauge be located? A. On the system, as far from the pump as possible B. Only at the pump inlet C. On the thermostat D. Outside the circuit, in open air 36. What criterion does the Lennox EL16KC1 manual, p. 23, require after shutting off and isolating the pump? A. Reach 500 microns for only an instant B. Maintain 5,000 microns for one minute C. Measure only while the pump is running D. Pressure must not exceed 500 microns for 20 minutes 37. In that Lennox test, the reading reaches 450 microns but rises to 900 during the 20-minute isolation period. Does it pass? A. Yes, because it was below 500 at some point B. Yes, because 900 is less than 1,000 C. Yes, if the pump has a high capacity D. No 38. Pressure rises after the pump is isolated. How should this be interpreted? A. It always proves the same fault B. It is always normal, no matter how much it rises C. Investigate the behavior and possible leaks, moisture or test connections D. Correct it by adding refrigerant without checking 39. According to the cited Lennox manual, can the equipment's compressor be used to evacuate the system? A. No B. Yes, if the thermostat is set low C. Yes, for less than five minutes D. Yes, in every R-454B system 40. Is 500 microns a universal guarantee of an adequate vacuum for any equipment? A. Yes, regardless of where it is measured B. No; the manufacturer's procedure and vacuum holding test must be met C. Yes, even if pressure rises afterward D. Yes, even without a vacuum holding test 5. Saturation, subcooling and superheat · Questions 41–50
41. What does refrigerant saturation describe? A. The temperature programmed into the thermostat B. The condition of transition between liquid and vapor at the corresponding pressure C. The compressor's maximum amperage D. The outdoor air temperature in every case 42. To calculate superheat for a blend with temperature glide, which reference is used? A. Bubble-point temperature (liquid) B. Always the average of both C. Dew-point temperature (vapor) D. Supply-air temperature 43. To calculate subcooling for that blend, which reference is used? A. Dew-point temperature (vapor) B. Outdoor temperature C. Thermostat temperature D. Bubble-point temperature (liquid) 44. What is the formula for superheat? A. Actual vapor temperature − vapor saturation temperature B. Vapor saturation temperature − actual vapor temperature C. Suction pressure − discharge pressure D. Outdoor temperature − indoor temperature 45. What is the formula for subcooling? A. Actual liquid temperature − liquid saturation temperature B. Discharge pressure − outdoor temperature C. Liquid saturation temperature − actual liquid temperature D. Vapor temperature − ambient temperature 46. Exercise: vapor at 55 °F and vapor saturation at 40 °F. What is the superheat? A. 95 °F B. 40 °F C. −15 °F D. 15 °F 47. R-454B exercise using the Honeywell chart: 110 psig → dew point 41.1 °F; suction line at 55.1 °F. What is the superheat? A. 16.2 °F B. 14.0 °F C. 15.1 °F D. 96.2 °F 48. R-454B exercise using the Honeywell chart: 300 psig → bubble point 99.6 °F; liquid at 89.6 °F. What is the subcooling? A. 10.0 °F B. 12.2 °F C. 10.4 °F D. −10.0 °F 49. What helps produce reliable superheat and subcooling measurements? A. Selecting the refrigerant with the most similar pressure B. Taking the reading before stabilization C. Using ambient temperature instead of pipe temperature D. The correct refrigerant, checked and properly located probes, and a stabilized system 50. Final R-454B case: suction 110 psig, dew point 41.1 °F and pipe temperature 61.1 °F; liquid 300 psig, bubble point 99.6 °F and pipe temperature 87.6 °F. What results do you get? A. Superheat 22.2 °F; subcooling 14.2 °F B. Superheat 20.0 °F; subcooling 12.0 °F C. Superheat 12.0 °F; subcooling 20.0 °F D. Superheat −20.0 °F; subcooling −12.0 °F