MÓDULO 07 · RESIDENCIAL

Heat pumps

Reversible-cycle heating, defrost and auxiliary backup.

Intermediate3 lessonsEdition: Oct. 20, 2026

LESSON 07.1

The idea of a reversible cycle

A heat pump can move energy indoors during heating and outdoors during cooling. In reversible systems, a valve changes the refrigerant path so the heat exchangers switch functions.

Not all heating comes from electric resistance. Some installations combine a heat pump with electric or fuel-fired backup. Identifying the mode and actual sequence is essential before interpreting temperatures.

THEORY → DIAGRAM → VIRTUAL PRACTICE

Cooling and heating: roles change

Compare exchanger roles. The reversing valve changes connections; the compressor does not pump backward.

Functional diagram
Cooling and heating: roles changeCompare exchanger roles. The reversing valve changes connections; the compressor does not pump backward. Indoors → Cycle reversal → OutdoorsIndoorsCycle reversalOutdoorsEvaporatorCondenserAbsorbs heatReleases heatHeat

On small screens, scroll the drawing horizontally. Every component is also available as a button.

Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.

Heat exchange changes; valve piping is not shown.

Think before continuing

Does switching to heating reverse compressor pumping direction?

Show explanation

No. Connections and exchanger roles change; suction and discharge retain their functions.

Sources and drawing scope

Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.

Open all interactive diagrams →

Check your understanding

Does the outdoor heat exchanger always operate as a condenser?

View the explained answer

No. In a heat pump it may act as an evaporator during heating; the functions change with the mode.

LESSON 07.2

Defrost and outdoor conditions

During heating, the outdoor heat exchanger may accumulate frost. Defrost is part of the manufacturer's intended control sequence. Its initiation and termination depend on the design, sensors and conditions.

Visible vapor during defrost may be normal, but persistent ice or failure to recover requires diagnosis. Bypassing sensors or forcing sequences without the equipment procedure does not resolve the problem.

THEORY → DIAGRAM → VIRTUAL PRACTICE

Cooling and heating: roles change

Compare exchanger roles. The reversing valve changes connections; the compressor does not pump backward.

Functional diagram
Cooling and heating: roles changeCompare exchanger roles. The reversing valve changes connections; the compressor does not pump backward. Indoors → Cycle reversal → OutdoorsIndoorsCycle reversalOutdoorsEvaporatorCondenserAbsorbs heatReleases heatHeat

On small screens, scroll the drawing horizontally. Every component is also available as a button.

Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.

Heat exchange changes; valve piping is not shown.

Think before continuing

Does switching to heating reverse compressor pumping direction?

Show explanation

No. Connections and exchanger roles change; suction and discharge retain their functions.

Sources and drawing scope

Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.

Open all interactive diagrams →

Check your understanding

Does every white cloud beside a heat pump indicate a leak?

View the explained answer

No. It may be vapor associated with defrost. Observe the context, duration and operation; stop using the equipment if there is a burning smell or another dangerous sign.

LESSON 07.3

Auxiliary heat, emergency heat and efficiency

Auxiliary heat may support the heat pump when available capacity does not meet demand or during certain sequences. Emergency mode, when provided, may change the heat source being used.

High energy use does not prove compressor failure: it may relate to controls, active backup heat, the building envelope or climate. Compare schedules, demand and data, rather than disabling protections to save energy.

THEORY → DIAGRAM → VIRTUAL PRACTICE

Control and power: a relay

Two separate circuits. The coil operates a contact through a mechanical link; there is no wire between those functions.

Circuit symbols
Control and power: a relayTwo separate circuits. The coil operates a contact through a mechanical link; there is no wire between those functions. Control contact → Coil K1 → Contact K1 (NO) → Load MControlLoad+−K1+−MMechanical link24 V DC24 V DC

On small screens, scroll the drawing horizontally. Every component is also available as a button.

Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.

Coil at rest; NO contact open.

Think before continuing

Is the dashed line between coil and contact a conductor?

Show explanation

No: it represents mechanical actuation. The electrical circuits remain separate.

Sources and drawing scope

Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.

Open all interactive diagrams →

Check your understanding

Why is it useful to record when auxiliary heat activates?

View the explained answer

It helps relate energy use and comfort to outdoor conditions, demand and the control sequence.