LESSON 06.1
The indoor and outdoor combination
In a central split system, the outdoor unit and indoor coil work with an air handler or other air-moving equipment. Straight cool usually describes cooling without reversing the cycle for heating; the system may include a separate auxiliary heat source.
Selection considers refrigerant, the expansion device, capacity and airflow, as well as electrical and control compatibility. Replacing only one part requires verification of the approved combination and its performance.
THEORY → DIAGRAM → VIRTUAL PRACTICE
The refrigerant path
Vapor-compression cycle in cooling mode. Pressure, phase and heat transfer are different concepts.
Functional diagramOn small screens, scroll the drawing horizontally. Every component is also available as a button.
Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.
Select a component or follow the sequence.
Reduces pressure; the outlet is shown as a liquid/vapor mixture.
Think before continuing
Does the entire low-pressure path contain only vapor?
Show explanation
No: there is a liquid/vapor mixture after expansion. Low pressure does not imply a single phase.
Sources and drawing scope
Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.
Check your understanding
Is matching tonnage enough when replacing a condensing unit?
View the explained answer
No. The indoor/outdoor combination, refrigerant, controls and installation conditions must be confirmed.
LESSON 06.2
Understand the operating sequence
A call for cooling starts a control sequence with delays and safety functions according to the design. The indoor fan, compressor and outdoor fan have different functions; one running does not prove the others are enabled.
The analysis follows the command from the thermostat to the equipment, using the exact diagram. Not all systems use conventional 24 V controls; some communicate digitally. A terminal letter is not permission to install a jumper.
THEORY → DIAGRAM → VIRTUAL PRACTICE
Control and power: a relay
Two separate circuits. The coil operates a contact through a mechanical link; there is no wire between those functions.
Circuit symbolsOn small screens, scroll the drawing horizontally. Every component is also available as a button.
Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.
Select a component or follow the sequence.
The energized coil operates contact K1. The dashed line indicates a mechanical link.
Coil at rest; NO contact open.
Think before continuing
Is the dashed line between coil and contact a conductor?
Show explanation
No: it represents mechanical actuation. The electrical circuits remain separate.
Sources and drawing scope
Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.
Check your understanding
There is indoor airflow but no cooling. What distinctions are useful in the diagnosis?
View the explained answer
Distinguish the demand, authorization from controls and safety devices, and the actual operation of each component before recommending a part.
LESSON 06.3
Check overall performance
A split system needs adequate heat exchange on both sides. Restricted indoor airflow, dirty coils, electrical problems or refrigerant-circuit faults can produce similar symptoms.
The temperature difference between return and supply must be interpreted with humidity, airflow, load and test conditions. A single temperature or pressure does not confirm correct charge or total capacity. Document conditions before and after the work.
THEORY → DIAGRAM → VIRTUAL PRACTICE
Saturation, superheat and subcooling
R-454B: real Honeywell chart points and hypothetical pipe temperatures. These are exercises, not target charging pressures or temperature differences.
Functional diagramOn small screens, scroll the drawing horizontally. Every component is also available as a button.
Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.
Select a component or follow the sequence.
Relate pressure and temperature at the same evaluation point. Probe location affects the result.
R-454B · 110 psig · Dew 41.1 °F. SH = 55.1 − 41.1 = 14.0 °F (7.8 °C). Pipe temperature chosen for the exercise; not an adjustment target.
Think before continuing
For R-454B, do SH and SC use the same saturation column?
Show explanation
No. Dew point for superheat; bubble point for subcooling. Do not apply this chart to R-410A or R-32.
Sources and drawing scope
Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.
Check your understanding
Does an apparently good temperature split prove that every room receives enough air?
View the explained answer
No. There may be a distribution or airflow problem. The evaluation must include the air system and measurement conditions.
Sources for further study
Reference readings: some resources are in English. Consult the current equipment manual before any work. Access to restricted documentation is not assumed.