MODULE 05 · RESIDENTIAL

Mini-splits and multi-splits

A visual introduction to indoor units, inverter drives, drainage and zone control.

Beginner3 lessonsEdition: Oct. 20, 2026

LESSON 05.1

Identify the complete system

A mini-split connects an outdoor unit to one or more indoor units through refrigerant piping and electrical or communication connections. Depending on the product family, indoor units may be wall-mounted, cassette, floor-mounted or ducted.

A multi-split shares an outdoor unit among several indoor units. Selection must comply with permitted combinations, capacity, piping lengths and elevation differences. A unit's appearance or matching BTU/h ratings do not prove compatibility.

THEORY → DIAGRAM → VIRTUAL PRACTICE

The refrigerant path

Vapor-compression cycle in cooling mode. Pressure, phase and heat transfer are different concepts.

Functional diagram
The refrigerant pathVapor-compression cycle in cooling mode. Pressure, phase and heat transfer are different concepts. Compressor → Condenser → Expansion → EvaporatorCompressorCondenserExpansionEvaporatorVapor · highLiquid · highMixture · lowVapor · lowReleases heatAbsorbs heat

On small screens, scroll the drawing horizontally. Every component is also available as a button.

Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.

Think before continuing

Does the entire low-pressure path contain only vapor?

Show explanation

No: there is a liquid/vapor mixture after expansion. Low pressure does not imply a single phase.

Sources and drawing scope

Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.

Open all interactive diagrams →

Check your understanding

Two indoor units have the same nominal capacity. Can they be interchanged?

View the explained answer

Only if the manufacturer approves that combination and the other requirements are verified. Equal nominal capacity does not mean compatible electronics or refrigerant circuits.

LESSON 05.2

What changes with an inverter drive

An inverter drive allows compressor speed to vary within defined limits. The control system coordinates demand, sensors, electronic expansion and fans. Current changing during operation may be normal.

Behavior depends on the model and operating mode. Diagnosis must record demand, temperatures and operating status before interpreting a reading. Power boards and DC buses present risks that require specific training.

THEORY → DIAGRAM → VIRTUAL PRACTICE

AC → DC → variable AC

Blocks in a typical electronic conversion. This is not a circuit-board schematic or a terminal map.

Functional diagram
AC → DC → variable ACBlocks in a typical electronic conversion. This is not a circuit-board schematic or a terminal map. Rectifier → DC bus → Inverter → MotorCA / ACRectifierDC busInverterMTypical conversion; functional blocks, not terminals.

On small screens, scroll the drawing horizontally. Every component is also available as a button.

Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.

Think before continuing

Are mains Hz enough to know inverter compressor speed?

Show explanation

No. The output stage and controller regulate the motor. Consult the manufacturer’s variables and methods.

Sources and drawing scope

Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.

Open all interactive diagrams →

Check your understanding

Does an amperage reading different from yesterday's prove a fault?

View the explained answer

No. Equivalent load, mode, speed and environmental conditions must first be compared, together with the equipment documentation.

LESSON 05.3

What can be observed without disassembly

The user can record the mode, selected temperature, visible codes, when the fault occurs and the condition of accessible filters. Condensate drainage and airflow deserve attention if water or ice appears.

A future technician learns to document those symptoms and consult the exact manual before working on the equipment. Cleaning, evacuation, connections and charging have specific procedures; a general explanation does not establish universal torque values, pressures or quantities.

THEORY → DIAGRAM → VIRTUAL PRACTICE

Return air, supply air and ventilation

Functional air path. Actual fan, filter and coil positions depend on the design.

Functional diagram
Return air, supply air and ventilationFunctional air path. Actual fan, filter and coil positions depend on the design. Return → Filter → Coil → FanReturnFilterCoilFanRoomSupplyRecirculation only in this example.

On small screens, scroll the drawing horizontally. Every component is also available as a button.

Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.

Recirculation only in this example.

Think before continuing

If the fan runs, do we know that fresh air is entering?

Show explanation

No. Toggle the drawing’s outdoor inlet: recirculation can operate without outdoor ventilation.

Sources and drawing scope

Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.

Open all interactive diagrams →

Check your understanding

The customer says the mini-split is dripping. Is that enough to conclude that it is low on refrigerant?

View the explained answer

No. Drainage, installation, ice and other conditions must be investigated. The symptom alone does not identify the cause.

Sources for further study

Reference readings: some resources are in English. Consult the current equipment manual before any work. Access to restricted documentation is not assumed.