LESSON 16.1
Marine air conditioning
Boats may have self-contained systems, split systems or chilled-water plants. The method of heat rejection depends on the installation; some use a seawater circuit.
Analysis begins with the actual diagram and the vessel and equipment manuals. Access, water, corrosion, electricity and flooding potential require specialized procedures. This lesson helps identify the architecture; it does not authorize work on seawater intakes or onboard electrical systems.
THEORY → DIAGRAM → VIRTUAL PRACTICE
Marine AC: water and refrigerant separated
Functional seawater path in an MCS system. It does not represent heights, mounting positions or an installation plan.
Functional diagramOn small screens, scroll the drawing horizontally. Every component is also available as a button.
Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.
Select a component or follow the sequence.
Seawater and refrigerant exchange heat across a wall without mixing in normal operation.
Think before continuing
Does seawater enter the refrigerant piping?
Show explanation
No. Both fluids remain separated by the heat exchanger.
Sources and drawing scope
Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.
Check your understanding
Can a rooftop procedure be applied directly to a marine system?
View the explained answer
No. Although they share refrigeration principles, heat exchange, installation, risks and maintenance requirements differ.
LESSON 16.2
Water-source and geothermal systems
A water-source heat pump exchanges energy with a water circuit. In a building, that circuit may share heat between zones and use central equipment to maintain its conditions.
A geothermal installation exchanges energy with the ground through a configuration designed for that location. Not every piece of equipment using water is geothermal, and not every water-source heat pump is a central chiller. Identify the source, distribution and terminals.
THEORY → DIAGRAM → VIRTUAL PRACTICE
Chiller: circuits that do not mix
Follow energy from the building through the refrigerant to outdoors. Heat-transfer lines are not pipes connecting fluids.
Functional diagramOn small screens, scroll the drawing horizontally. Every component is also available as a button.
Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.
Select a component or follow the sequence.
Water exchanges heat with the load and evaporator without entering the refrigerant circuit.
Three separate circuits; they only exchange heat.
Think before continuing
Does chilled water mix with refrigerant in the evaporator?
Show explanation
No. They exchange energy through heat-exchanger surfaces while remaining separate.
Sources and drawing scope
Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.
Check your understanding
Does a shared water loop in a hotel prove that a geothermal field exists?
View the explained answer
No. Verify how that loop exchanges energy: with the ground, a tower, a boiler or another designed solution.
LESSON 16.3
Window units, portables, PTAC and PTHP
Room equipment has different configurations: window units, portables with exhaust air, packaged terminal units and packaged terminal heat pumps. Each family has its own installation and performance requirements.
For a hotel, comparing nominal capacity is not enough. Review ventilation, noise, drainage, controls and maintenance. PTAC and PTHP describe terminal configurations; they should not be confused with a chilled-water fan-coil.
THEORY → DIAGRAM → VIRTUAL PRACTICE
Cooling and heating: roles change
Compare exchanger roles. The reversing valve changes connections; the compressor does not pump backward.
Functional diagramOn small screens, scroll the drawing horizontally. Every component is also available as a button.
Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.
Select a component or follow the sequence.
In cooling it absorbs heat from the space; in heating it delivers heat to the space.
Heat exchange changes; valve piping is not shown.
Think before continuing
Does switching to heating reverse compressor pumping direction?
Show explanation
No. Connections and exchanger roles change; suction and discharge retain their functions.
Sources and drawing scope
Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.
Check your understanding
Can two units that fit a wall opening simply replace each other?
View the explained answer
No. Dimensions, support, drainage, power supply, ventilation and installation compatibility must be verified.
Sources for further study
- DOE · Heat pump systems ↗
- Trane · Technical training resources ↗
- DOE · Central air conditioners and heat pumps ↗
Reference readings: some resources are in English. Consult the current equipment manual before any work. Access to restricted documentation is not assumed.